3 CONDUCTOR |
3 CONDUCTOR COPPER WIRE GAUGE SIZE |
|||||||||
WATTS PER FIXTURE |
# of FIXTURES |
VOLTS |
APPROX. AMPS |
#14 |
#12 |
#10 |
#8 |
#6 |
#4 |
#2 |
75 |
2 |
120 |
1.3 |
740 |
1150 |
1920 |
2955 |
4710 |
7445 |
11535 |
75 |
3 |
120 |
1.9 |
505 |
790 |
1315 |
2025 |
3220 |
5090 |
7895 |
75 |
4 |
120 |
2.5 |
385 |
600 |
1000 |
1535 |
2445 |
3870 |
6000 |
150 |
2 |
120 |
2.5 |
385 |
600 |
1000 |
1535 |
2445 |
3870 |
6000 |
150 |
3 |
120 |
3.8 |
255 |
395 |
655 |
1010 |
1610 |
2545 |
3945 |
150 |
4 |
120 |
5 |
190 |
300 |
500 |
765 |
1220 |
1935 |
3000 |
250 |
2 |
120 |
4.2 |
230 |
355 |
595 |
915 |
1455 |
2300 |
3570 |
250 |
3 |
120 |
6.3 |
150 |
235 |
395 |
610 |
970 |
1535 |
2380 |
250 |
4 |
120 |
8.5 |
110 |
175 |
290 |
450 |
720 |
1135 |
1760 |
HORSEPOWER |
DEPTH |
MOUNTING |
1/2 HP |
15 - 25 inches |
Horizontal |
1/2 HP |
26" and above |
Vertical |
1-5 HP |
18 - 35 inches |
Horizontal |
1-5 HP |
36" and above |
Vertical |