SINGLE PHASE 3 CONDUCTOR
3 CONDUCTOR COPPER WIRE GAUGE SIZE
UNIT
VOLTS
APPROX. AMPS
#14
#12
#10
#8
#6
#4
#2
1/2 HP
120
5
175
275
450
700
1120
1770
2750
1/2 HP
208-240
2.5
670
1040
1730
2660
4240
6710
10400
4 CONDUCTOR: REQUIRED ON ALL 1 - 10 HP SINGLE PHASE & THREE PHASE AERATORS
SINGLE PHASE 4 CONDUCTOR
4 CONDUCTOR COPPER WIRE GAUGE SIZE
UNIT
VOLTS
APPROX. AMPS
#14
#12
#10
#8
#6
#4
#2
1 HP
120
18
---
---
125
195
310
490
760
1 HP
208-240
9
---
285
480
740
1170
1860
2880
2 HP
208-240
12
---
210
360
550
880
1395
2165
3.5 HP
208-240
15
---
---
285
440
700
1115
1730
5 HP
208-240
26
---
---
165
250
400
645
1000
7.5
240*
Consult Factory
10
240*
56
---
---
---
115
190
300
460
THREE PHASE 4 CONDUCTOR
4 CONDUCTOR COPPER WIRE GAUGE SIZE
UNIT
VOLTS
APPROX. AMPS
#14
#12
#10
#8
#6
#4
#2
1 HP
208-240
5
---
600
1000
1540
2450
3870
6000
1 HP
440-480
2.5
---
2540
4230
6510
10360
16390
25400
2 HP
208-240
6
---
500
830
1280
2040
3225
5000
2 HP
440-480
3
---
2115
3525
5425
8640
13655
21170
3 HP
208-240
10
---
300
500
770
1225
1935
3002
3 HP
440-480
5
---
1270
2115
3250
5185
8195
12700
5 HP
208-240
12
---
250
415
640
1020
1610
2500
5 HP
440-480
6
---
1060
1760
2710
4320
6825
10585
7.5 HP
208-240
24
---
125
200
320
510
800
1250
7.5 HP
440-480
12
---
525
880
1350
2160
3415
5290
10 HP
208-240
33.5
---
---
145
230
360
575
896
10 HP
440-480
16.7
---
---
630
975
1550
2450
3800
*The 7.5 and 10 HP, Single Phase, models require a minimum voltage of 220.
AquaMaster® recommends consulting a licensed electrician to properly
size any underground cable from the main power source to our control
panel. Please contact AquaMaster® if assistance is required.
*Actual voltage to motor will affect
  your fountain’s performance.
Return to Cad-Specs-Details